Radon Reduction in New Construction: Double-BarrierApproach

December 12th, 2017

A double-barrier design with the space between the barriers having little resistance to the gas flow is described for those parts of homes and buildings that interface with the soil or surficial rock to reduce soil-gas (radon) entry into structures. The outside or soil-side barrier interfaces with the soil. A barrier placed on the soil under the subslab aggregate is an important element in this design. This forms the outer barrier for the floor. The subslab aggregate forms a permeable layer, while a plastic membrane above the aggregate, the slab, and caulking for the inner barrier. If hollow blocks are used, barrier coatings can be placed on both the soil side and interior wall of the blocks, while the hollow space in the blocks forms the permeable space. The hollow-block walls are connected to the subslab aggregate to form a small, interconnected permeable volume that can be managed in the following ways to reduce soil-gas entry into the structure. 1. Sealed. 2. Passively vented to outdoor air. 3. Passively depressurized using an internal stack. 4.Actively depressurized. 5.Actively pressurized. In addition to basements with hollow-block walls, the double-barrier technique can be adapted to solid wall, crawl space, and slab-on-grade construction, including various combinations.